• IT
  •    |   
  • DE
  •    |   
  • EN
  •    |   
  • FR
  •    |   
  • RU
  •    |   
  • CN

Logo Isolcell Italia

Automation system

Isolcell ItaliaMULTIPLEX is a centralized O2 and CO2 analyser with a high precision microprocessor and a PC. O2 measurement is by a paramagnetic sensor. CO2 measurement is by an infrared sensor of latest generation.


The equipment works automatically and is able to analyse sequentially 48 cold rooms.

It can also be connected in a network withother analysers.
Using he programme ISOSOFT in the PC, with interfaces MULTIPLEX controls all the devices to maintain the room set-points


TECHNICAL FEATURES:

SYSTEM AUTOMATION - MULTIPLEX
Technical data
GAS TYPE O2 CO2
MEASUREMENT RANGE 0-25 % *0-10 %
ACCURACY 0,1 % 0,1 %
WARM UP TIME 5 min.
GAS SAMPLING pump
MEASURMENT PRINCIPLE paramagnetic cell infrared
POWER SUPPLY 220-240V. A.C.
DIMENSIONS mm 600x640x1970
WEIGHT 180 Kg

 

阅读全文...

LECAIsolcell LECA has conceived a new desk-top O2 and CO2 analyser. It has a microprocessor to automatically control a C.A storage plant. O2 measurement is carried out by a paramagnetic analyser. CO2 measurement is carried out by an infrared sensor.


This device is easy to use and set, that’s why it is popular with operators.


TECHNICAL FEATURES:

AUTOMATION SYSTEMS - LECA
Technical data
TYPE OF GAS O2 CO2
MEASUREMENT RANGE 0-25 % *0-10 %
ACCURACY 0,1 % 0,1 %
WARM UP TIME 5 min.
GAS SAMPLING pump
MEASUREMENT PRINCIPLE Paramagnetic infrared
POWER SUPPLY 220-240V. A.C.
DIMENSIONS mm 540x650x450
WEIGHT 42 Kg

阅读全文...

LECASELECA is a desk-top O2 and CO2 analyser equipped with a microprocessor to automatically control a controlled atmosphere storage plant. Oxygen concentration is measured by an electrochemical cell and the CO2 measured by an infrared sensor.


A microprocessor controls the sequential analysis of the cold rooms and activatesthe CO2 absorbers as well as the injection of oxygen. Seleca has an internal pump for the sample collection.

AUTOMATION SYSTEMS - LECA
Technical data
TYPE OF GAS O2 CO2
MEASUREMENT RANGE 0-25 % *0-10 %
ACCURACY 0,1 % 0,1 %
WARM UP TIME 5 min.
GAS SAMPLING pump
MEASUREMENT PRINCIPLE electro chemical infrared
POWER SUPPLY 220-240V. A.C.
DIMENSIONS mm 540x650x450
WEIGHT 42 Kg

 

阅读全文...

ISOSOFTISOSOFT is a software for the automatic control of the Dinamic Controlled Atmosphere Plant on windows basis provided with modular expansion for the control of the following plants:


  • Intelligent CO2 Scrubbers control
  • Automatic plant for the pressure test control
  • Display of the fluorescence sensors for DCA provided with ISOSTORE system
  • Humidification plant control
  • Refrigeration plant control
  • Analyser autocalibration control

Isolcell ItaliaIsolcell ItaliaIsolcell ItaliaIsolcell Italia
Isolcell ItaliaIsolcell ItaliaIsolcell ItaliaIsolcell Italia

阅读全文...

Isolcell International

Isolcell - International

Newsletter

Seguici su twitter

SELECA ist ein Tischanalysengerät, welches sowohl für die O2- als auch für die CO2-Messung geeignet ist. http://t.co/C7kJ7P34

by Isolcell

Seguici

Google+